The following requirements for the house installation must be met so that the Docking Station can be installed: 


  • max. cross-section of the supply line: 6mm². 
  • max. fuse protection of the supply line: 16 A, the fuse protection must be matched to the supply line
  • Residual current circuit breaker: type A (30mA), taking into account national specifications
  • Rated voltage: 230/400 V 
  • Rated frequency: 50 Hz